Baxi boiler e160 error code

  • Baxi boiler e160 error code. Whilst the user guide says that E160 indicates a component fault it does not go any further. Low water pressure is a common boiler issue. You first need to check the pressure gauge and if it’s low, repressurise it until it’s at 1 to 1. E110 fault code is caused due to the limit stat being triggered generally due to the boiler overheating. Check the cable PCB/gas valve, replace PCB if necessary. Should be 3-5µA Note: The gas isn’t reaching the burner and the boiler does not ignite. If flue is clear outside a Gas Engineer will be required to fix, the flue inside the boiler has a sensor, this will be triggered if the flue gas passing it is too hot or if the Suggested repair solutions may be provided by a link to a repair page. In both cases, make sure you completely close the filling loops to prevent leaks. E168. Maximum flow temperature exceeded, flow temperature rise rate too high or excessive difference between flow and return temperature. This could be because the boiler has been reset after developing a fault or because there has been an external issue, such as a fault with the electrical supply. Check the cable PCB/gas valve and gas valve plug. We also are fully qualified and experienced to service, upgrade and repair all types of boiler, and carry out repairs to existing hot water and central If your boiler has any of these settings, check they’re in the right place: Timer: some boilers have the ability to switch on or off at certain times of the day. Baxi Boilers. Jun 30, 2023 · Try resetting the boiler: Sometimes this can do the trick, go to the boiler and hold the reset button for 1-3 seconds. While you hold down the green lever, be sure to check the pressure Apr 19, 2024 · The E133 code on a Baxi boiler indicates that the boiler has experienced an interruption in gas supply, a failure in the ignition process, or the flame has not been detected after several attempts. a few weeks back the boiler came up with E160 error( fan speed error). You can follow this step to fi Feb 21, 2024 · The Baxi, Potterton and Main E119 boiler fault code indicates low boiler pressure, so you must repressurise your boiler to fix it. 14 Version 1 133Ignition failure. Error Code. Please note: This video is intended "Discover common Baxi boiler faults such as problems with the pilot light, thermostat and pressure gauge. Hire a Local Verified tradesmen near you today. Dec 30, 2023 · Adjust the water pressure by slowly opening the filling loop valves – watch the pressure gauge rise. Push the green lever down. All moving parts will eventually fail, most will last for a very long time but some will fail earlier than expected. Check the sensor. E133: Ignition lockout. If this solves the problem, then happy days, if not you will have to call an engineer. According to Potterton, the boiler fault code E160 is related to a lock out due to fan issue and here we Apr 28, 2014 · BAXI GA RANGE – E160 – BOILER ERROR CODE - Fan fault. Having the timer set to off could be what causes hot water to stop working. Restart the heating system and observe the boiler's response – it should now operate without the E1 code appearing. 1. General cause for this would be a blockage in the system or a faulty pump which will require the assistance of a gas engineer to repair the fault. Ensure radiators are bled of air. 1) the pressure fluctuation is caused by the water in the system getting hot then cold. Possible Cause. Once the boiler heats water, it’s pumped around the heating system (pipework, towel rails and radiators). The good thing is this is a simple fix you can do yourself. 330 Boiler intermittently generates an E160 Code. Not an overly massive problem and can be fixed quite easily baxi have service engineers that can assist at a set fee or alternatively any gas safe registered engineer such as ourselves with boiler diagnostic knowledge will be able to fix this issue. Feb 16, 2014 · Anonymous user. You have to press the button to reset the boiler. Jul 7, 2021 · E119 error is due to low pressure and probably leaking in the pipe line, usually happens on the adjustment knob near radiator. If the Sensor is working properly replace the main control board. baxitraining. System water pressure high – try bleeding water from your radiators. Registered office address: Baxi Heating UK Limited, Brooks House, Coventry Road, Warwick, United Kingdom, CV34 4LL Company registered in England and Wales: 3879156 VAT registration number is 604665837 E160 is fan Fault OR Relating to fan or flue fault if the boiler has been installed correctly i would suggest the fault lies with the fan itself the boiler tries to fire up you hear the boiler kick into life try to fire (it will do this 3 times) then E160 appears If Yes Replace Fan universalheatingsparesuk byron October 2010 Error: “E160”; Description: Anomaly of the fan. ; Cause: The fan within the boiler is not functioning correctly. Get your heating back on track Home Advice Hub: What is the Baxi boiler e160 fault / error code? Your questions answered by Verified Tradesmen. It is located on the right side, just before the boiler’s front. Call your installer or Baxi Customer Support if E165 persists. For boilers with inbuilt filling loops, the process is more or less the same. Feb 8, 2024 · Baxi Boiler Fault Codes – Summary. The wiring harness between the fan and PCB being damaged or degraded. Jul 10, 2023 · This article will provide valuable information regarding Potterton boiler fault codes, five common issues, and their corresponding solutions. May 21, 2024 · Here’s how to solve the Baxi E119 fault code with this new easy fill valve. This is usually caused by a sludge build-up. If the pump is not functioning, it may need repair or replacement. E160 on a Baxi or Potterton boiler is a very reliable fault code. On the flip side, a fan for a Baxi Solo 3 is nearly £200. If the boiler does not relight, or the code is displayed regularly contact your installer or Baxi Customer Support. E1 is common among brands like Ideal Boilers, Baxi, Potterton, and Jan 30, 2024 · The E125 fault code on a Baxi boiler indicates a circulation problem, usually resulting from low water pressure. A common culprit for this fault on Baxi boilers is a lack of pressure. . shopstuff. this is the reason boilers have expansion vessel. Disconnect the outdoor temperature sensor and take an ohm reading using chart B. Pritesh recommended the Hive Smart Active Heating consisting of a wireless smart thermostat, receiver and hub to enable remote use. If the sensor is out of calibration replace it. Main. 88737 with a registered office at 5/5 Fault Code. 5. Why is myfan not running? The fan motor has failed. Feb 10, 2023 · To fill the boiler with water, turn the red knob counter clockwise, which you can see under it. Apr 28, 2014 · Flue overheat thermostat Installer to check system circulation. Nov 11, 2013 · The boiler is a Baxi neta-tec combi ga range. Oct 1, 2022 · My Baxi Luna HT 1. Overheat lock out. E130 Fault code on a Baxi indicates a flue fault, all the homeowner can do is ensure the flue on the outside of the property is not blocked by debris or vegetation. Self-fix is possible with our instructions, no need for a Gas Safe registered engineer. Are yo … read more BAXI LUNA DUO-TEC TROUBLESHOOTING GUIDE. Fault codes on these boilers are shown as alternative flashing E or E1 and then two other numbers. Interruption of gas supply (internal error). 1 GREEN FLASH. E10. When the fault code is displayed on the control panel, that’s a sign of bad/no circulation. 24|7 Home Assist Limited is authorised and regulated by the Financial Conduct Authority FRN: 935754. Listen for any unusual noises coming from the pump, and verify that it is running smoothly. This will protect major parts like a pump. - Emergency Plumber work undertaken Call 01628 369247 Jul 19, 2021 · Overall Score: 48%: Reliability: 3 stars: Customer Score: 2 stars: Engineer recommendation: 3 stars: Ease of fixing a common fault: 4 stars: Ease of servicing 3 stars Possible Cause: Boiler Max temperature exceeded for gradient (or overtemperature) Probable pump jammed or air in the circuit or Safety thermostat sensor tripped Dec 3, 2023 · James Elston is our resident boiler replacement and heating expert here at Boiler Central. I also want to upgrade the heating controls from an old mechanical thermostat and control unit to a smart heating and hot water control system. https://www. Mar 3, 2024 · The Baxi E160 error code specifically points to a fan fault within the boiler. Want to learn more? Check out our product training courses here www. Check electrics: Make sure all the electrics to the boiler are on. E160 on a Baxi boiler is a very reliable fault code. Quick fault finding guide on a Baxi fan fault. Mobile 0795 857 8737 Baxi Duotec 28 He Error Code E133 Fault code E133 was displayed when I arrived so reset and tried hot water. If a fault occurs on the boiler an error code may be shown by the facia display. Check the water flow switch. ukJoin our Baxi Works i Apr 25, 2014 · Let’s Fix it is an online community that exists so we can all help each other fix things. Mar 22, 2015 · I am having difficulty fixing a fault on a 5 yr old Baxi Duo tec 28 he boiler, and hope someone can help from their experience. If the code has an A prefix this is a PCB programming code and should not be seen; this is usually due to a power supply fluctuation and resetting the boiler should clear it. Once you hear water running into it, wait until the pressure reaches 1. Flue thermistor error: E110: Boiler overheat error: E119: low water pressure error: E125: Primary water circulation error: E131: Flue overheat lockout error: E133: Ignition error: E160 / E161: Fan error: E164: Pressure sensor fault: E167: Printed circuit board (PCB) error: E168: Printed circuit board (PCB) lockout error: E193: Circulation error E160 is fan Fault OR Relating to fan or flue fault if the boiler has been installed correctly i would suggest the fault lies with the fan itself the boiler tries to fire up you hear the boiler kick into life try to fire (it will do this 3 times) then E160 appears If Yes Replace Fan universalheatingsparesuk byron October 2010 Feb 7, 2024 · Stay informed about Potterton boiler fault codes for optimal performance and safety of your Potterton boiler with our informative resource The UK's Leading Boiler Comparison Website 0330 818 6219 Apr 25, 2014 · Let’s Fix it is an online community that exists so we can all help each other fix things. Don’t attempt to open the boiler unit by Standard Warranty Terms & Conditions To activate your second year free warranty you must register your boiler with heateam the service division of Baxi Heating UK Ltd either by completing and returning the registration card or calling our telephone registration line on 0800 013 7989. The simple answer to this is that the boiler will tell you. With over 20 years experience in the boiler installation industry, James ensures that he knows everything there is about our Gas Safe boiler installations, energy saving and home heating solutions. Gas supply fault. Resolve issues with combi, system and standard boilers. The codes are a flashing number, either two or three digit, preceded by the symbol E :- - E followed by 20, 28, 40, 160 or 321 indicates possible faulty components. Nov 22, 2020 · An issue with the central heating pump – the pump is struggling to push water around the system. Fault with fan or fan wiring. Solution. The 160 fault code on your Baxi boiler could be due to: A fan with a stuck motor, or worn bearings. " 2 Years Free Warranty - register today To receive your 2 years free warranty please complete the form supplied with the boiler or simply call heateam, the service of Baxi Heating UK Ltd on 0800 731 1644. Let’s Fix it is an online community that exists so we can all help each other fix things. Outdoor Temperature Sensor fault. once you sort out the expansion vessel check that the boiler its not self Anonymous user. 01 – . Unfortunately, these are not always easy to understand. E118. Possible fault in air/gas unit or loose connection to gas valve. Found not just in Baxi boilers but also in Potterton and Here is Baxi trainer Darren taking you through how to diagnose and correct error code E04 10 on a Baxi 400 Combi 2 boiler. The boiler fired up but Baxi duo tec 28he fault code E133. E110. Description / Possible Cause. When the E160 fault code occurs in the Baxi boiler, the cause of this error is fan-induced, and the Baxi will remain in a self-locked state. E53. Mar 15, 2013 · E168 seems to be the Baxi code displayed when the boiler doesn't know whats wrong. The main control board is constantly checking the speed of the fan and comparing it to an expected reading, if a reading is incorrect it will display a E160 fault code. co. E119: Low water pressure switch activated. Jan 16, 2024 · Find full lists of Baxi boiler error and fault codes with possible causes and fixes. E160. you seem to have two different issues. Inspect and clean the pipes: Examine the pipes and components of the system for any blockages Mar 31, 2022 · Boiler fan replacement costs vary for one simple reason; no two boiler fans are the same price. For instance, a Worcester Junior 28I fan is less than £100. You’ll hear water running into the central heating system. This leads me to believe the problem might be with the pcb. 00: Loss of communication between gas valve and boiler board. once you sort out the expansion vessel check that the boiler its not self Jun 5, 2018 · GA boilers - What to do with Baxi E133 error code. E133. Feb 19, 2024 · Baxi 600 Heat and Main Eco Compact Heat Boiler Fault Codes. Poor combustion – flue terminal may be blocked. Feb 19, 2024 · Description / Possible Cause. 5 bar. E119. E130: Flue NTC operated. It can normally be reset but will go back the same fault. Baxi boiler reset button. Posted by Ollie Lyon on Wednesday 18th January 2023, updated on Thursday 4th January 2024 Ensure radiators are bled of air. The fan plays a crucial role in ensuring safe operation by expelling harmful combustion Mar 3, 2024 · James Elston is our resident boiler replacement and heating expert here at Boiler Central. E125 Troubleshooting Tips: Check the pump: Ensure that the pump is operating correctly. Turn the selector switch to the reset position and hold for at least 5 seconds. BBS Plumbing and Heating are professional Gas Safe Register installers for Baxi gas boilers and OFTEC registered installers for Baxi oil-fired boilers in the greater London area. jcsplumbingheating. E163. Description. uk/ What is a Baxi E160 fault code? An E160 on a Baxi or Potterton boiler means the fan is not working. Fault Code. E160: Fan fault. Ecoblue. All Boiler codes and Manual Available. If all ok and E133 persists - contact engineer to visit. Apparently this keeps happening whenever my mum has the central heating on and the water on at the same time I hope someone can help me with a quick and easy solution! Mar 25, 2024 · Key takeaways. ukHow to resolve the E133 error on a Baxi Main Boiler Enter your mobile number below and we'll send the download link straight to your phone. The multi-plug on the PCB not being plugged in correctly. Online Manual of all Boiler. If your system is set lower than 1. E117. Fault Code Possible Cause; E110: Over heated – try bleeding your radiators: E119: Water pressure too low: E125: Overheat – try bleeding your radiators Mar 7, 2024 · E1 usually means that a boiler has low water pressure, causing the boiler not to work. Thank you, ***** ***** 165 could mean that your boiler has detected a problem but can't work out exactly what it is. due to high pressure your expansion vessel may have blown the diaphragm so pumping air into it will not solve the issue. Ignite my Boiler has taken over the servicing of my Vaillant ecoTEK boiler. Warning: You're currently on an iOS device, click the App Store button to be sent directly to the app. Visit now! Feb 23, 2024 · Struggling with a Baxi boiler error code? Our guide deciphers common faults and offers both DIY fixes and when to call a professional. E110: Safety thermostat operated. This could be caused by a problem with the settings or even a blown seal. E125: Circulation fault. May 20, 2022 · Fault Code: Possible Cause: H. The boiler keeps intermittently throwing up a default code E168. This seems like a very simple and unlikely cause, but it really does happen. The E1 boiler code can be triggered by a number of different faults, each identified with the digit sequence following the 'E1', for example E133. Displayed overheat of the primary water or flue system has occurred. We have a Baxi Duo tech combi 33 HE. When the unit calls for heat/hot water, the blower motor "stutters". Here's a breakdown of common fault codes related to E1 faults on Baxi boilers, along with their possible causes and solutions: E119: Low Water Pressure - If your boiler shows the E119 code, it means the water pressure is too low. Apr 24, 2014 · Let’s Fix it is an online community that exists so we can all help each other fix things. Apr 25, 2014 · Let’s Fix it is an online community that exists so we can all help each other fix things. Company No: 09438900 and VAT number: 223099322. For a green lever, look underneath the boiler. Sometimes you have to hold it down for a few seconds, but on some Baxis, it just needs to be pressed and released. Apr 25, 2014 · Fan speed error, too slow Engineer visit required Can’t crack the Baxi boiler fault codes? No worries, this blog will help you understand what these codes on different Baxi boiler models mean. If it’s freezing outside and the E160 fault code has suddenly appeared, the condensate pipe could be the culprit. This may follow a power cut, try reset. Check gas is turned on, if prepayment meter check there is credit. Thermostat: easily done, but check to see the thermostat dial’s pointing to your preferred level of warmth. The PCB being faulty. NB Some fault codes are only applicable to a specific range of boilers only. Mar 23, 2022 · 24|7 Home Rescue is a trading name of 24|7 Home Assist Limited registered in England & Wales. This article provides an in-depth analysis of Baxi boiler fault codes and outlines solutions for sensor errors, gas/air supply issues, and high-temperature warnings. -Check for proper polarity and grounding to the unit -Check for adequate gas pressure and flow to the unit refer to the installation manual -Check µA (micro-amps) reading from flame sensor. Flow/return sensor temperature test. Over heated – try bleeding your radiators. E193; Pre-Circulation fault. Low pressure in the system or pressure sensor faulty. Link. Engineer visit required. Eventually solved my problem with a new board, traced the problem as follows: the boiler would start ok and then the 240v on the pcb to the gas valve would fail switching off the gas. Jan 11, 2020 · if you have not found what you are looking for, please contact us. E154. According to Baxi, the 125 boiler fault code occurs when there is an issue with water circulation. Check radiators are bled Asides from leaks, there are other problems that can cause a boiler to lock out including fault codes: 110 (overheating), to 160 (a faulty fan) or even 166 (air pressure switch fault). The insurance policy is underwritten by Evolution Insurance Company Limited which is registered in Gibraltar No. If you’re experiencing issues with your Baxi 105 HE boiler then, given its age, we would recommend upgrading it to a modern a-rated energy efficient boiler. Everyone has some experience in fixing things around the home, garden, buildings, vehicles, boats and on and on. ; Solution: Check the fan for any obvious issues and reset the boiler if necessary. Nov 30, 2023 · The Baxi E133 Fault: A Comprehensive Guide Introduction: Hello there, dear Heatlab readers! Today, we're diving into a rather common, yet perplexing issue for many homeowners and professionals alike – (Psst, it's an ignition fault!) the notorious Baxi E133 fault. Learn how to diagnose and resolve these issues with the assistance of a professional, Gas Safe registered engineer. 5 bar, then close. Learn Baxi Boiler Error Codes here! Jul 19, 2021 · What are the Main Boiler Error Codes? This blog provides a complete list of fault codes for all makes of Main boilers. Blockage – A blockage somewhere in your central heating is preventing water from circulating properly. May 20, 2022 · When trying to fix a boiler, you may come across some error codes. Oct 2, 2020 · The Baxi 105 HE is a discontinued condensing combi boiler with an energy-efficiency rating of B. E131. Mar 2, 2018 · For more information visit: https://www. Low boiler pressure will cause your boiler to not fire up when it drops below a certain pressure. 2 GREEN FLASHES. Open the valve until the pressure reaches 1. so my question is, I can get a new pcb for £65, much cheaper than a tradesman would charge, then it is only 4 mounting screws and 4 or 5 cable connections to the board. The condensed gases are prone to freezing, especially when the condensate pipe is small and isn’t routed close to vertical. One can remedy this by increasing the pressure within the system, often by topping up the boiler via the filling loop. Feb 17, 2024 · To reset a modern Baxi boiler (eg 600 or 800), you must find the reset button. Repressurising the boiler: If the boiler is really low on pressure repressurise it up to 1 bar > 1. Fault Code Possible Cause; H. Dec 28, 2009 · After switching the boiler off, then on again the thing works only to fail intermittantly throughout the day. Once the gauge reads between 1 and 2 bar, you've hit the sweet spot; it’s time to close the valves. Is your boiler pressure falling regularly? Chances are, your boiler is leaking. 5 Bar (Check out our video on how to repressurise a Baxi main eco compact boiler) Consult a professional: If you have gone through these steps and the low primary system water pressure issue persists, it is advisable to seek assistance from a Apr 25, 2014 · BAXI GA RANGE – E110 – BOILER ERROR CODE - Overheat. E168: PCB (printed circuit board) fault. This is a button that has ‘Reset’ on it. 5 bar then it won’t operate correctly. As a guideline, expect to pay in the region of £225-275 including parts and installation. When fault code E160 appears on the Baxi, the fan may not be running, the fan may not be running at the required speed, or the fan may be burned out. ol ui ls vi yy jk xs dg fa tp